变电站工程质量通病防治控制措施内容摘要:
........................31 设备安装缺件 ...........................................................................................................31 各类设备安装缺少部件、螺栓,接地端子缺少弹簧垫等 ............................................31 ★ ............................................................................................................................31 27 ...................................................................................................................................31 螺栓安装不规范 .......................................................................................................31 螺栓安装不出扣、未紧固、或与构件安装不紧密 ......................................................31 ★ ............................................................................................................................31 28 ...................................................................................................................................31 设备及安装螺栓生锈 ................................................................................................31 因设备制造、安装等原因导致设备及安装螺栓生锈(非个别现象) ..........................31 29 ...................................................................................................................................31 构件外观质量存在明显缺陷 ......................................................................................31 构支架等构件镀锌质量差(存在锌瘤、锌疤、露铁等明显缺陷),或因施工造成损伤 31 30 ...................................................................................................................................31 电缆敷设不规范 .......................................................................................................31 动力电缆与通信电缆无措施混放,电缆施放交叉无序,电缆承受外力,电缆沟容量、电缆支架承力等与施放的电缆不匹配等 ........................................................................31 31 ...................................................................................................................................31 电缆封堵不规范 .......................................................................................................31 该封堵处未封堵、封堵不完整、封堵材料老化脱落、封堵工艺差等 ..........................31 32 ...................................................................................................................................31 电缆二次接线不规范 ................................................................................................31 端子排上接线存在缺失螺丝或不坚固, 不同截面芯线插接入同一端子同一侧,一个端子同一侧接线数超过 2 根,备用芯裸露等 ....................................................................31 33 ...................................................................................................................................32 电缆沟积水 ..............................................................................................................32 电缆沟局部积水,排水不畅,有淤泥等杂物堆积 ......................................................32 34 ...................................................................................................................................32 静电地板铺设不规范 ................................................................................................32 静电地板水平度超标,破损、翘曲,底部支撑不可靠 ...............................................32 35 ...................................................................................................................................32 可能产生 不均匀沉降的不同构(建)筑物间未留置变形缝 ........................................32 建(构)筑物与台阶、散水等未留置变形缝 .............................................................32 36 ...................................................................................................................................32 设备垫片安装不规范 ................................................................................................32 垫片安装随意 ,超出三片安装垫片或垫片安装不牢固 .................................................32 37 ...................................................................................................................................32 压接管不满足规范要求 .............................................................................................32 设备线夹、母线压接管等压接部位弯曲度超标,飞边等未处理等 ..............................32 38 ...................................................................................................................................32 尾线朝上的线夹未设排水孔 ......................................................................................32 尾线朝上的线夹未设排水孔 ......................................................................................32 39 ...................................................................................................................................32 端子箱、屏柜等柜间接地联线缺失 ...........................................................................32 未设置或断裂、脱落等 .............................................................................................32 40 ...................................................................................................................................32 控制台内线缆凌乱 ....................................................................................................32 控制台内的电源线、网 络线、视频线等未整理,凌乱 ...............................................32 1 1. 编制目的 为规范开展质量通病防治工作, 落实质量通病防治技术措施,提高质量通病防治工作效果,进一步提高 110kV 南驿 变电站 工程质量 为了更好地进行施工监理,控制质量、控制工期、控制投资, 加强监理单位对施工质量的过程控制, 提高监理工作绩效, 有效防范各类施工质量事故的发生, 持续提升工程建设质量做好管理工作,特制订本工程质量通病防治控制措施。 指导本工程监理项目部及监理人员开展监理质量通病防治控制工作,最终实现工 程质量目标。 2. 编制依据 1.合同文件 2.法律法规文件 1) 中华人民共和国建筑法(主席令第 46 号 2020 年 7月 1日起执行) 2)建设工程质量管理条例(国务院令第 279 号 2020 年 1月 30 号起执行) 3) 中华人民共和国合同法(主席令第 65 号 2020 年 1月 1日起施行) 4) 中华人民共和国 工程建设标准强制性条文 电力工程部分 2020 年版 5)中华人民共和国 工程建设标准强制性条文 房屋建筑部分 2020 版(建标〔 2020〕 219 号) 6)中华人民共和国 工程建设标准强制性条文 工业建筑部分(建标 〔 2020〕40号) 3.工程管理文件 1) 《国家电网公司电力建设工程施工技术管理导则》(国家电网工〔 2020〕153 号) 2) 《国家电网公司输变电工程达标投产考核办法》(国家电网基建〔 2020〕146 号) 3) 《国家电网公司输变电优质工程评选办法》(国家电网基建〔 2020〕 4) 国家电网公司《关于利用数码照片资料加强输变电工程安全质量过程控制的通知》 (基建安全 [2020]25 号 ) 5) 《关于强化输变电工程施工过程质量控制数码照片采集与管理的工作要求》(国网基建质量。变电站工程质量通病防治控制措施
相关推荐
监理单位 验收结论 监理工程师 年 月 日 注:施工作业人员质量责任登记应按部位和工序分别签名[变、配电所安装工程 ]电气装置 母线装置 检验批质量 验收记录表 单位工程名称 分部工程名称 分项工程名称 验收部位 施 工 单 位 项目负责人 施工质量验收标准名称及编号 《高速铁路 电力 工程施工质量验收标准》 TB10757— 2020 施 工 质 量 验 收 标 准 的 规 定
—— 你我的人生大舞台 深圳成 功口才培训中心 13 会议欢迎词 女士们,先生们: 你们好。 我非常愉快地代表大会组委会向应邀前来参加会议的全体嘉宾表示诚挚的欢迎。 本次大会邀请了中国演讲界知名演讲家、《演 讲与口才》创刊人邵守义教授,全国普通话推广委员会主任、广州市长黎子流先生,中国 核能 演讲与口才协会关爱先生。 本次大会必将成为语言学界、演讲学界的一次盛会,成为演讲学界的一个里程碑。
绝缘性要求,并在出厂时同高压开关一起完成出厂各项相关试验。 位置 等级 好处 缺点 CT端子箱 推荐 安装简单,易于实现 无 独立柜体内 替换方法 增强电磁兼容性能 增加安装成本 5 d)平均无故障时间: 50000h。 GIS局放监测 DTM800 GIS局放在线监测技术指标 表 3 GIS局放在线监测技术指标 序号 参 数 检测范围 1 检测方法 UHF检测 2 最小放电量 10 pC 3
施工及验收标准 ISO9001 质量体系管理文件及 HSE 管理手册 国家及行业现行的、最新的规范、规程和标准规范及验评标准。 《建筑电气工程施工质量验收规范》 GB5023032020 《涂装作业安全规程安全管理通则》 GB 7691 《建筑灭火器配置设计规范 》 GB501402020 《建筑防腐蚀工程质量检验评定标准》 GB502241995 《建筑施工安全检查标准》 JGJ591999
或少都会存在些许问题,例如分格线条的边线局部粗糙;一次砼与二次砼相接处砼表面有浮浆以及气孔等,具 体处理方法如下: ① 套管处理 由于套管均埋设在线槽内,管头不易切割,需用打毛钎小心击打,除去 凸出部分,然后以高强度砂浆灌实。 ② 分格线条处理 弹线打磨处理边线,使其横平竖直,然后贴胶纸涂刷沥青漆。 ③ 浮浆、气孔处理 用干水泥粉堵塞气孔