gc3800操作手册内容摘要:

Figure 10 点火探头部件在 FID 塔内的定位 ............................ .......... ........ ...................91 Figure 11 FID 横截面图 .................................................... ...............................................92 Figure 12 TSD标样中各组份的分子结构式 .................... .......... ....................................97 Figure 13 TSD 分解图 ................................................... ..............................................100 Figure 14 TSD 横截面图 ................................................. ..............................................103 Figure 15 TCD 灵敏度和放大率 ............................................................ ......................111 Figure 16 ECD 横截面图 ................................................. ............................................122 Figure 17 放射性警告标签 –工厂已经安装 ........................ .......... ................................124 Figure 18 放射性警告标签 –用户安装 ........................................................................124 Figure 19 3800 GC 以太网联接 ................................... ..................................................127 Figure 20 10Base2 以太网组建 ...................................... ...............................................128 Figure 21 3800 GC 与 Star 工作站的联接 ............................ .......................................128 Figure 22 可接受的和不可接受的联接 /切断方式实例 .................. .......... .......................129 Figure 23 复杂的 3800 GC 与 Star工作站的联接 .......................... ............................130 Figure 24 模拟信号联接端子 ........................................................................................131 Figure 25 3800本地自动化 ...........................................................................................134 附表 Table 1用于液体进样器和进样阀的气路系统 . .......... .......... ..........................................42 Table 2 检测器的色谱柱安装深度 ....................... ...........................................................53 Table 3 毛细柱密封压环的选择 ..... ............................................... ..... .......... ..................53 Table 4 用于恒流的压力程序控制 ..................... ......... ................ ..................................56 Table 5使用氦气做载气时对于常用色谱柱压力设定与出口流速 ................ .......................57 Table 6 使用氢气做载气时对于常用色谱柱压力设定与出口流速 ......................................57 Table 7 分流进样的典型条件 .................... .......................................................................59 Table 8 恒温不分流进样参数 ......................... .......... .......... .......... .................................59 Table 9 程序升温的不分流进样 ................... .......... ........................................................60 Table 10柱头进样 ....................................... ....................................................................62 Table 11大体积进样 .................................... ...................................................................62 Table 12 1079进样器测试样品 .................... .....................................................................63 Table 13 常用密封压环的一般紧固和重复紧固 ......... .......... .......................................... 67 Table 14 1041进样器的载气流速 ..................................... ...............................................69 Table 15 1041进样器的测试样品 .............................................. .......................................70 Table 16 1041进样器的测试色谱条件 ............................... .......... ........ .......... ................71 Table 17 常用密封压环的一般紧固和重复紧固 ............... .......... .......... ...........................75 Table 18 1061进样器的载气流速 .......... .........................................................................76 Table 19 1061进样器的测试样品 .................................... ....................... ........................78 Table 20 1061 I进样器的测试色谱条件 .............. .......... .......... .......... .............................79 Table 21 TSD 气体、压力、纯度和流速 ............ .......... .......... ........................................100 Table 22 ECD 气体、压力、纯度和流速 ................................. .......... .............................120 3800 键盘和显示 7 3800 键盘及显示屏 3800气相色谱仪的键盘和显示屏系一完美结合,使其界面最大限度地发挥最简单易学和易于使用的特性。 本章将介绍键盘和显示屏的布局和功能,以及一步一步地介 绍如何在 3800气相色谱仪上进行系统配置和建立方法 文中内容以同样的形式出现,您会自己对系统熟悉起来。 首先学习显示屏,然后是基本的键盘功能例如 ENTRY和 INSTRUMENT键,最后是方法的特殊功能。 3800的显示屏 3800的显示屏使您易于访问所有的 GC功能。 屏幕以翻页的形式出现,最多包含11行的内容。 一般地,所有的从属于特定组件或功能的信息都可以出现在单独一个屏幕上。 然而如建立一个方法中有关检测器的一节,可以有两个或更多页屏幕用于显示一些功能。 在这些情况下,页码会清楚地显示在屏幕的上端, page1 of 2 ,等等。 某些页面包含时间程序参数表,例如进样器或色谱柱升温程序,外部事件控制或柱头压等等。 一个例子是 3800时间事件表格的页面,用来程序控制 1079进样器的分流状态,显示如下: 3800 键盘和显示 8 从每一页的第一行可以识别当前激活的方法,当前可以编辑的方法, GC是在本地控制或遥控(如果 3800是在遥控状态下就会有一个计算机图标出现在显示屏的第一行的中间)。 最后显示的是当前的运行时间和激活方法的结束时间。 ( ACTIVE)激活方法代表其中的方法参数是当前正在工作的,显示屏的第二行出现的也是该方法的状 态。 1079进样器屏幕的上方显示的分别是设定温度和实际温度以及当前的分流比。 ( EDIT)编辑方法代表的是最近您所选择编辑的方法,并且它的参数显示在屏幕的中段。 3800柱温的方法参数的第一页显示在下面。 任何对方法的改变都会自动更新存贮。 .然而,要让这些改变影响到 GC的下一次分析,编辑的方法必须要被激活。 在编辑一个方法以后,您必须激活它以保证它的参数在下一次运行中使用。 3800的每页屏幕上每一个方法参数的正下面都有提示。 基于光标在屏幕上的位置,提示行指示的是该位置所允许输入的数值范围。 3800显 示屏最下面一行显示的是功能键,例如在特定的 3800屏幕上激活的特殊功能。 例如,在柱温方法屏幕的下面就有 Turn Oven On(打开柱温箱 ) 和 Turn Oven Off(关闭柱温箱 )的字样指示相应功能键,使您可以打开或关闭柱温箱。 注意:屏幕上状态部分和方法参数部分是用粗实线分开的 3800 键盘和显示 9 3800 键盘 3800 键盘是排开在多行显示屏周围的,具有以下分区: 分区 说明 页 和 光 标(PAGE,CURSOR) 用于在显示屏并同位置和页之间浏览 表编辑 (TABLE EDIT) 用于表格编辑的输入,例如温度 程序或时间事件 . 输入 (ENTRY) 包含数字键 (0 9 ,十进制点,减号,和无限 ), 增加 (INCR )和减少 (DECR )键 , 输入键 . 帮助键给出对光标所在位置的参数的相关解释。 仪器 (INSTRUMENT) 包含设置和状态键,允许你改变 GC 的配置和查看安装部件的状态。 GC 控制 (GC CONTROL) 容许直接对进样器,柱温,检测器等项目的访问以建立方法和查看状态。 自动化 (AUTOMATION) 当前没有激活。 方法 (METHOD) 允许你编辑或者激活八个之中的任何一个方法。 开始 / 停止(START/STOP) 包含开始和停止键,以手动开始或停止一个运行。 未准备 ,准备 ,和运行指示灯指示 GC 的状态。 以下是这些分区的详细叙述。 3800 键盘和显示 10 页和光标键 页和光标键允许你在页与页之间和在屏幕上到处移动。 按压上页箭头键上到前一页 ,同样,按压下页箭头键到下一页。 如果没有前一页或下一页存在,那么按压这些键没有效果。 如果屏幕中包含能修改的参数 ,光标将会出现。 光标箭头键是用来移动光标从一参数到另一个参数的。 这。
阅读剩余 0%
本站所有文章资讯、展示的图片素材等内容均为注册用户上传(部分报媒/平媒内容转载自网络合作媒体),仅供学习参考。 用户通过本站上传、发布的任何内容的知识产权归属用户或原始著作权人所有。如有侵犯您的版权,请联系我们反馈本站将在三个工作日内改正。